Error Message Codes
Error Message Codes
The following error message codes may appear on Zowe Launcher SYSPRINT. Use the following message code references and the corresponding reasons and actions to help troubleshoot issues.
Zowe Launcher informational messages​
ZWEL0001I​
component %s started
Reason:
Component <component-name>
started.
Action:
No action required.
ZWEL0002I​
component %s stopped
Reason:
Component <component-name>
stopped.
Action:
No action required.
ZWEL0003I​
new component initialized %s, restart_cnt=%d, min_uptime=%d seconds, share_as=%s
Reason:
Component <component-name>
initialized.
restart_cnt
- Number of attempts to restart the component in case of failuremin_uptime
- Minimum uptime that the component can be considered as successfully startedshare_as
- One of<yes|no|must>
which indicates whether child processes of the component start in the same address space. See documentation for _BPX_SHAREAS for details.
Action:
No action required.
ZWEL0004I​
component %s(%d) terminated, status = %d
Reason:
Component <component-name>
(<pid>
) terminated with status <code>
.
Action:
No action required.
ZWEL0005I​
next attempt to restart component %s in %d seconds
Reason:
Component failure detected.
Action:
No action required. The component <component-name>
will be restarted in <n>
seconds.
Zowe Launcher error messages​
ZWEL0030E​
failed to prepare Zowe instance
Reason:
Failed to prepare the Zowe high availability (HA) instance.
Action:
Check previous messages in the Zowe Launcher SYSPRINT to find the reason and correct it.
ZWEL0038E​
failed to restart component %s, max retries reached
Reason:
Maximum retries reached for restarting component <component-name
>.
Action:
Check <component-name>
configuration and correct the maximum restart count via configuration attribute restartIntervals
if needed, then restart the component by using z/OS MODIFY command F ZWESLSTC,APPL=STOP(<component-name>)
ZWEL0040E​
failed to start component %s
Reason:
Failed to start component <component-name>
.
Action:
Check <component-name>
configuration and correct if needed, then either 1) start the component manually by using z/OS MODIFY command F ZWESLSTC,APPL=STOP(<component-name>)
or 2) restart the entire HA instance